Linke Cable Technology (DongGuan) CO.,LTD

Linke Cable Technology (DongGuan) CO.,LTD

Manufacturer from China
Verified Supplier
1 Years
Home / Products / EV Charger Cable /

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Contact Now
Linke Cable Technology (DongGuan) CO.,LTD
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrWilliam Liu
Contact Now

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Ask Latest Price
Video Channel
Place of Origin :Guangdong, China
Brand Name :Linke
Certification :UL;ISO9001;ISO13485;IATF16949;TPU
MOQ :1000m
Price :Negotiable
Packaging Details :According to requirement
Delivery Time :7-15 days
Payment Terms :Advance 30% deposit and ship after receiving 70% final payment
Supply Ability :100000000
Package Gross Weight :212.000kg
Origin :China
Model NO. :type 1
Color :Black
IP Grade :IP65
Lead Time :7-15days
HS Code :94054090
Phase :Three Phase
Customization :Available
Rated Current :32A
Cable Length :5meter or Custom
Name :Charging Cable
Shipping Cost :about shipping cost and estimated delivery time.
Return&refunds :You can apply for a refund up to 30 days after receipt of the products.
Copper :Tinned Copper
Package Size :850.00cm * 850.00cm * 580.00cm
Core :Multiple
Jacket 1 :TPU
Jacket 2 :XLPE
Transport Package :Roll
Specification :800 roll
Trademark :LINKE
conductor material :copper/Tinned Copper
Conductor Type :Twisted wire
Exterior material :customize:PVC、PE、LSFOH、silicone rubber
insulating materials :customize:PVC、PE 、XLPE、EPR、SIR
specifications :0.1-450mm²
rated voltage :300-600V
rated temperature :-60± 200℃
colour :customize
type :insulated
package :By roll
Currency :US$
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Three Phase Type1 Extension Cable with Tinned Copper Connectors 50A and 80A

16A 32A Type 2 Electric Vehicle EV Charging Cable with TUV&UL

Product Description

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Usage gauge DC Charing line Cable: 350A 1/0AWG x 4C + 18AWG (CP:shielding)1C+ 14AWG×1C + 18AWG x 2P+18AWG x 1C OD=35mm TPE Sheath

This is a DC 350 Ampere fast Electric Vehicle charging Cable.It is composed of 4 power cables,one green ground cable, one yellow coaxial wire, one blue control cable, 2 pairs of signal wire.And cable has good insulation performance,which can meet the requirements of standard flame retardant, oil resistance, aging resistance and easy to bend.Also In line with the standards of UL,it's export to the American market, with large output current, large power and fast charging speed advantages.
Product Parameters

Reference Standard:UL 2263

UL No.:E364879

Construction

Features

1.Conductor

Rated temperature:-50℃~105℃

  Material: Bare Copper

Rated Voltage:1000V

2.Insulation

Conductor Resistance(at 20°C):8AWG≤2.23Ω/km;10AWG≤3.51Ω/km;16AWG≤14.1Ω/km;Test method Comply with UL 2556

  Material: TPE

15°C Insulation Resistance:8AWG≥34Ω.m;10AWG≥34Ω.m;16AWG≥45Ω.m;Test method Comply with UL 2556

  Color:Black,red,Green/Yellow or other

Dielectric Voltage: 4.0kV AC/1min(8AWG),3.0KV AC/1min(10AWG), 2.0KV AC/1min(16AWG). No Breakdown. Test method Comply with UL 2556

3.Filler

Bending Radius Min:≥6OD.

  Material: cotton yarn

Hot Shock:150℃/1h No cracks Test method Comply with UL 2556

4.Tape

Flame Test:FT1.Test method Comply with UL 2556

  Material:Non-woven fabrics

Insulation tensile strength:Before Aging 5.5Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556

5.Sheath

Insulation Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556

  Material: TPE

Jacket tensile strength:Before Aging 8.3Mpa;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556

  Color: Black or Orange

Jacket Elongation:Before Aging200%;After Aging(136°C/168H)≥75%Original.Test method Comply with UL 2556

Cold Bending Test:-40°C/4H,NO Cracking.Test method Comply with UL 2556

Hot Shock Test:150°C/1H,NO Cracking.Test method Comply with UL 2556

Type

Main Lines Size & E

Signal Lines Size

Permissible ampacity@20°C ambient Ref.

Over diameter Ref. mm

EVC 1001

10AGW/2+10AGW

22AGW(20AGW/18AGW/16AGW)0-6

32A

12.0±0.5

EVC 1002

9AGW/2+10AGW

40A

13.8±0.5

EVC 1003

8AGW/2+10AGW

48A

15.0±0.5

EVC 1004

6AGW/2+8AGW

80A

18.9±0.5

EVC 1005

3AGW/4+12AGW(14AGW/10AGW)

18AGW(20AGW/22AGW)0-8

170A(200A)

28.3±1.0

EVC 1006

2AGW/4+12AGW(14AGW/10AGW)

200A(250A)

31.0±1.0

EVC 1007

1/0AGW/4+12AGW(14AGW/10AGW)

300A-350A

36.5±1.0

EVC 1008

4AGW/2+14AGW

120A

21.0±1.0

EVC 1009

1AGW/4+14AGW

250A(300A)

34.0±1.0

UL 2263 EV charging cable (Suitable for CCS1)

Reference Standard:UL 2263

UL No.:E364879

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Construction Features
1.Conductor Rated temperature:-40℃~105℃
  Material: Bare Copper Rated Voltage:300V;600V or 1000V
2.Insulation Flame Test: VW-1 Test method Comply with UL 2556
  Material: TPE Min: Bending Radius: ≥6*OD
  colour:Black,Red,Green/Yellow or other Dielectric Voltage: 1.5kVac/1min. No Breakdown Test method Comply with UL 2556
3.Filler Cold Bending:-40℃/4h No cracks Test method Comply with UL 2556
  Material: cotton yarn Hot Shock:150℃/1h No cracks Test method Comply with UL 2556
4.Tape Oil Resistance:IRM902, 60℃/168h Tensile and Elongation ≥70% Unaged value
  Material:Non-woven fabrics Crush Resistance:S≤12AWG 4.45kN, 12AWG<S≤2AWG, 11.1kN, 2AWG<S 15.6kN
5.Sheath Weather Resistance:720hin a xenon arc weatherometer, No cracks
  Material: TPE Environmental Requirements:Compliant with RoHS
  Color: Black or Orange(customizable)

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Type Size Conductor Stranded OD mm Ref. Max. Conductor resistance mΩ/m@20℃ Permissible ampacity@20℃ ambient Ref. Over diameter Ref. mm Packing M/Reel (Ref.)
600V or 1000V EVE(TPE) 3×16AWG 1.5/1.2 14.1 12A 10.8±0.5 1000m/700#
3×14AWG 1.9/1.2 8.88 16A 11.8±0.5 800m/700#
3×12AWG 2.4/1.2 5.58 23A 14.3±0.5 500m/700#
3×10AWG 3.0/1.2 3.51 32A 15.6±0.5 500m/700#
2×8AWG+10AWG 4.3/3.0 2.23/3.51 46A 20.9±0.8 500m/950#
2×6AWG+8AWG 5.4/4.3 1.40/2.23 63A 23.4±0.8 400m/950#
3×16AWG+1×18AWG 1.5/1.2 14.1/22.4 12A 11.4±0.5 800m/700#
3×14AWG+1×18AWG 1.9/1.2 8.88/22.4 16A 13.5±0.5 500m/700#
3×12AWG+1×18AWG 2.4/1.2 5.58/22.4 23A 14.5±0.5 500m/700#
3×10AWG+1×18AWG 3.0/1.2 3.51/22.4 32A 15.8±0.6 500m/700#
2×8AWG+10AWG+18AWG 4.3/3.0 2.23/3.51/22.4 46A 20.9±0.8 500m/950#
2×6AWG+8AWG+18AWG 5.4/4.3 1.40/2.23/22.4 63A 23.4±0.8 400m/950#
2×4AWG+6AWG+18AWG 6.6/5.4 0.882/1.4/22.4 75A 27.0±0.9 300m/950#
3×16AWG+2×18AWG 1.5/1.2 3.51/22.4 12A 12.2±0.5 500m/700#
3×14AWG+2×18AWG 1.9/1.2 8.88/22.4 16A 14.1±0.5 500m/700#
3×12AWG+2×18AWG 2.4/1.2 5.58/22.4 23A 15.1±0.6 500m/700#
3×10AWG+2×18AWG 3.0/1.2 3.51/22.4 32A 15.8±0.6 500m/700#
2×8AWG+10AWG+2×18AWG 4.3/3.0 2.23/3.51 46A 20.9±0.8 500m/950#
2×6AWG+8AWG+2×18AWG 5.4/4.3 1.40/2.23 63A 23.4±0.8 400m/950#
2×4AWG+6AWG+2×18AWG 6.6/5.4 0.882/1.4 75A 27.0±0.9 300m/950#
2×2AWG+4AWG+2×18AWG 8.2/6.6 0.555/0.882 100A 30.5±1.0 400m/1200#
2×1/0AWG+2AWG+4×16AGW 10.5/8.2 0.349/0.555 200A 38.0±1.0 250m/1200#

2×3/0AWG+1/0AWG

(2×3/0AWG+4AWG+6X18AWG)
3/0AWG Ground line minimum 4AWG
13.05/10.5 0.219/0.349 260A 45.0±1.0 150m/1200#
4X1-0AWG+4AWG+6X18AWG 10.4/6.5 0.351/0.882/23.6 300A/350A 45.7±1.2 150m/1200#
300V EVJE(TPE) 3×16AWG 1.5/1.2 3.51/22.4 12A 9.5±0.3 1200m/700#
3×14AWG 1.9/1.2 8.88/22.4 16A 10.2±0.5 1000m/700#
3×12AWG 2.4/1.2 5.58/22.4 23A 11.4±0.5 800m/700#
3×16AWG+1×18AWG 1.5/1.2 3.51/22.4 12A 10.5±0.5 1000m/700#
3×14AWG+1×18AWG 1.9/1.2 8.88/22.4 16A 11.1±0.5 80m/700#
3×12AWG+1×18AWG 2.4/1.2 5.58/22.4 23A 12.2±0.5 500m/700#
3×16AWG+2×18AWG 1.5/1.2 3.51/22.4 12A 11.3±0.5 800m/700#
3×14AWG+2×18AWG 1.9/1.2 8.88/22.4 16A 12.0±0.5 800m/700#
3×12AWG+2×18AWG 2.4/1.2 5.58/22.4 23A 13.1±0.5 500m/700#
The number of signal wires can be 0~6, or more, the signal wire conductor specifications can be 16AWG, 18AWG, 20AWG, 22AWG.

The above product specifications, sizes, and structures may be changed due to technological progress. Similar specifications can be designed and manufactured according to customer needs.

Detailed Photos

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

2,Low viscosity appearance
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Company Profile

Wire and cable manufacturer Linke Cable Technology Co., Ltd is a leading cable supplier in China. In the past over 10 years,

Linke Cable has been focusing on R&D, production and marketing of wire and cable. Linke provide various cables&custom

cable solutions for all over the world. We are specialized in EV charging cable, medical cable, silicone cable, spring cable,

braided cable, towlobe cable, UL wire, automotive cable, etc.

At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach

to develop better cables for customers and improve the quality of one's life.

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors

Exhibition:

Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors


Our certification:
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors
Three Phase Type1 Extension EV Charger Cable 50A 80A with Tinned Copper Connectors



We past UL1007,UL1185,UL1672,UL10070,UL10483,UL1015,UL1569,UL10012,UL10269

(Single conductor,thermoplastic insulation)
UL2095,UL2129,UL2468,UL2586,UL2725,UL20233,UL20280,UL20963,UL2103,UL2463,UL2517,UL2587,UL2835,

UL20276,UL20549,UL21198,2104,UL2464,UL2576,UL2661,UL2919,UL20279,UL20886,UL21664

ISO9001 and ISO13485,TS16949

CNR- Appliance Wiring Material,

Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.

Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.

Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2

FAQ

1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last.

Welcome to visit us. We'll pick you up in Shenzhen.

2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.

3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.

4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.

5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company

Inquiry Cart 0